    Hardware Equipment Malfunction Reference Table

    Fault Symptom


    Possible Causes


     Solutions


    Pan-tilt does not self-test after power on


    Power supply or transformer failure


    Reconnect the cables


    Power supply or transformer failure


    Check if the local power supply is functioning properly and if AC24V is working correctly


    Insufficient power output of the power supply


    Replace with a suitable power supply


    Faulty power board


    Contact the supplier for replacement of the power board


    Fault Symptom Possible Causes Solutions


    Poorly connected or open-circuit control board wires


    Check the wiring of the control lines, ensure proper and secure connections


    Poorly connected Ethernet cable


    Check if the Ethernet cable is securely connected


    Incorrect PTZ protocol or baud rate settings 


    Reconfigure based on dip switch settings

    PTZ protocol or baud rate


    Image loss during PTZ rotation


    nsufficient power output of the power supply 


    Replace with a suitable power supply


    Blurry image


    Focus set to manual


    Change focus setting to auto


    Dirt on the protective cover


    Clean the protective cover glass